Use: | A variety of gas-drive or suction-lift samplers have been developed for permanent installation in a single borehole to allow multilevel sampling. |
Description:
Minimal purging is required because there is little mixing between incoming water from the formation and stagnant water. Samples are collected using tubing that runs from the surface to each individual sampling device.
Analytes:
1. Non-Halogenated VOCs | 5. PAHs | 9. Inorganics |
2. Non-Halogenated SVOCs | 6. Pesticides/Herbicides | 10. Explosives |
3. Halogenated VOCs | 7. Metals | 11. TPHs |
4. Halogenated SVOCs | 8. Radionuclides |
Media:
Soil: | Ground Water: | Surface Water: | Gas/Air: |
Not Applicable | MINIMUM | Not Applicable | MODERATE |
Cross-contamination is a potential concern for installations requiring grout to isolate sampling points.
Maximum Depth: | Up to 100 feet. |
Production Rate: | Sample is available after a short amount of time. |
Investigation Derived Waste Volume: | Medium volume of waste. |
Technology Status: | Commercially available technology with moderate field experience. |
Certification/Verification: | Technology has not participated in CalEPA certification and/or CSCT verification program. |
Relative Cost per Sample: | Mid-range expense. |
Limitations:
ASTM Standards/EPA Methods:
No applicable ASTM standards or EPA methods are cited for this technology.
Previous Page | Sample Access/Collection Matrix | Sample Analysis Matrix | Home | Areas of Interest | Next Page |