navbar.gif (6338 bytes)

4 COLLECTION TOOLS

4.5 PORTABLE GRAB SAMPLERS

4.5.2 Pneumatic Depth-Specific Samplers


Use: Pneumatic depth-specific samplers (commonly called syringes) are used to collect ground water samples at discrete intervals.

Description:

A variety of samplers are available in which the sample container is pressurized or evacuated. When the container is opened or pressure released, the sample enters the collection instrument.

Analytes:

1. Non-Halogenated VOCs 5. PAHs 9. Inorganics
2. Non-Halogenated SVOCs 6. Pesticides/Herbicides 10. Explosives
3. Halogenated VOCs 7. Metals 11. TPHs
4. Halogenated SVOCs 8. Radionuclides

Media:

Soil: Ground Water: Surface Water: Gas/Air:
Not Applicable MINIMUM MINIMUM Not Applicable

Sample does not come into contact with atmospheric gases.

Maximum Depth: 200 feet plus. Minimum well diameter: 1.5 inches.
Production Rate: Sample is available after a short amount of time. 0.01 to 0.2 gallon capacity.
Investigation Derived Waste Volume: Small volume of waste.
Technology Status: Commercially available technology with moderate field experience.
Certification/Verification: Technology has not participated in CalEPA certification and/or CSCT verification program.
Relative Cost per Sample: Mid-range expense.

Limitations:

ASTM Standards:

D 4448 - 85a Sampling Ground Water Monitoring Wells.
D 6232 Standard Guide for Selection of Sampling Equipment for Waste and Contaminated Media Data Collection Activities.

Previous Page Sample Access/Collection Matrix Sample Analysis Matrix Home Areas of Interest Next Page