navbar.gif (6338 bytes)

6 SAMPLE ANALYSIS TOOLS for VOCs, SVOCS, and PESTICIDES

6.2 EX-SITU ANALYSIS

6.2.22 Semiconductor Sensors


Use: Screening for chlorinated hydrocarbons in water and gas samples.

Description:

Semiconductor sensors are designed to respond electrically to the substance of interest.

Analytes:

1. Non-Halogenated VOCs
3. Halogenated VOCs

Media:

Soil/Sediment Water Gas/Air
Requires extraction to gas phase BETTER BETTER
Selectivity: Technique measures the contaminant indirectly.
Susceptibility to Interference: Medium.
Detection Limits : 100-1000 ppb (soil); 1-50 ppb (water).
Turnaround Time per Sample: Minutes.
Applicable To:
Screen/Identify Characterize Concentration/Extent Cleanup Performance Long-Term Monitoring
BETTER ADEQUATE BETTER BETTER
Quantitative Data Capability: Data become quantitative with additional effort.
Technology Status: Commercially available technology with limited field experience.
Certification/Verification: Technology has not participated in CalEPA certification and/or CSCT verification program.
Relative Cost per Analysis: Least expensive.

Limitations:

ASTM Standards/EPA Methods:

No applicable ASTM standards or EPA methods are cited for this technology.


Previous Page Sample Access/Collection Matrix Sample Analysis Matrix Home Areas of Interest Next Page