navbar.gif (6338 bytes)

6 SAMPLE ANALYSIS TOOLS for VOCs, SVOCS, and PESTICIDES

6.2 EX-SITU ANALYSIS

6.2.28 Free Product Sensors


Use: The free product sensor is designed to give an accurate measurement of liquids lighter than water.

Description:

A 1.5-inch (38-mm) diameter probe includes a highly visible light with audible signal to indicate the presence of water and light immiscible liquids.

Analytes:

11. TPH

Media:

Soil/Sediment Water Gas/Air
Not Applicable BETTER Not Applicable
Selectivity: Technique measures a part of the compound.
Susceptibility to Interference: Low.
Detection Limits : 500+ ppm (soil); 100+ ppm (water).
Turnaround Time per Sample: Minutes.
Applicable To:
Screen/Identify Characterize Concentration/Extent Cleanup Performance Long-Term Monitoring
BETTER BETTER BETTER BETTER
Quantitative Data Capability: Does not produce quantitative data.
Technology Status: Commercially available and routinely used field technology.
Certification/Verification: Technology has not participated in CalEPA certification and/or CSCT verification program.
Relative Cost per Analysis: Least expensive.

Limitations:

ASTM Standards/EPA Methods:

No applicable ASTM standards or EPA methods are cited for this technology.


Previous Page Sample Access/Collection Matrix Sample Analysis Matrix Home Areas of Interest Next Page